IAPSO seawater ampoules contain standard seawater with a "known" salinity
value. The label on the IAPSO
vial shows the "Date" on which the IAPSO batch was made, the K15,
2 x K15, and the salinity value.
IAPSO ampoules are used as universal standards when measuring salinity
samples. Table 6 below shows
the IAPSO batches used for HOT cruises 1-157.
HOT-21 (November 17-18, 1990, Chief Scientist C. D. Winn) is excluded
from this table because the crane on R/V Naina was too long for a safe
deployment of the CTD and the cruise was aborted due to increasing seas
and gale force winds.
| IAPSO Batch # |
HOT Cruise # |
|
P103 |
1 |
|
P110 |
2-12 |
|
P111 |
13-19 |
|
P112 |
20, 22 |
|
P114 |
22-25, 26-31 |
|
P115 |
25, 32-40 |
|
P118 |
41-49, 50-51, 54 |
|
P121 |
49, 52-53, 54-57 |
|
P123 |
58-69 |
|
P128 |
69-80, 86-87 |
|
P130 |
80-85, 87-88 |
|
P132 |
89-100 |
|
P134 |
101-105 |
|
P135 |
104-115 |
|
P136 |
115-125 |
|
P138 |
126-134, 140 |
|
P140 |
135-139, 141-148, 150 |
|
P141 |
149, 151-157 |